Part Number Hot Search : 
MAX1169 P6KE200A D64H4B M1MA15 CY621 APW7067 38D9UXM A101M
Product Description
Full Text Search
 

To Download SCB945300 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 S/BIP/SCB945300/B/07/02/2003
page 1 / 3 F/GB
Relais Statique Double Double Solid State Relay
* Sortie AC synchrone : 12-280Vac-50A x 2 . * Une Commande pour 2 voies. * Connexion de Puissance et de Commande par vis. * Possibilite de protection IP00 en option:Capot 1K470 000. * 12-280VAC -50A x 2 Zero-Cross AC Output. * One Control for 2 legs. * Power and Control connections by screw therminal. * Protection IP00 optional (1K470 000).
SCB945300
8-30 VDC control 2x50A/230VAC output
Aplication typique/Typical application
L1
L1
L2
L3
N
+
1 input output T1 L2 2
-
input
output T2
Caracteristiques de commande (a 20C) / Control characteristics (at 20C) DC-AC Parameter Symbol Min Nom Tension de commande / Control voltage Uc 8 Courant de commande / Control current (@ Uc nom ) Ic 5 Tension de relachement/Release voltage Uc off 1 Resistance interne / Input internal resistor fig.1 Rc 1000 Tension inverse / Reverse voltage Urv Caracteristiques d'entree-sortie (a 20C) / Input-output characteristics (at 20C) Isolement entree-sortie/Input-output isolation @500m Uimp/Ui 4000/3300 Isolement sortie-semelle/Output-case isolation @500m Uimp/Ui 4000/3300 Isolement entre voies / Leg 1-Leg 2 isolation @500m Uimp/Ui 4000/3300 Caracteristiques generales / General characteristics Parameter Poids/Weight Plage de temperature de stockage / Storage temprange Plage de temperature de fonctionnement/Operating temprange Resistance thermique Jonction-Case/Junct.-Case thermal resistance(1 leg)
fig. 1 :Caracteristique d'entree / Control characteristic Max 30 30 Unit V mA V V V V V
30 25 Ic (mA) 20 15 10 5 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30
30
Uc (V)
Conditions
Symbol
Typ. 110 -40/+100 -40/+100 0,5
Unit g C C C/W
Proud to serve you
All technical caracteristics are subject to change without previous notice. Caracteristiques sujettes a modifications sans preavis.
celduc
r e l a i
s
S/BIP/SCB945300/B/07/02/2003
page 2 / 3 F/GB
Caracteristiques de sortie(a 20C) / Output characteristics (at 20C) Parameter Tension de charge / Load voltage Plage tension de fonctionnement / Operating range Tension crete (ecreteur de tension) / Peak voltage (clamping voltage) Niveau de synchonisation / Synchronizing level Tension d'amorcage / Latching voltage Courant nominal AC1/ AC1 nominal current Courant de surcharge non repetitif /Non repetitive overload current Chute tension directe crete/ On state voltage drop Courant de fuite etat bloque/ Off state leakage current Courant de charge minimum / Minimum load current Temps de fermeture/ Turn on time Temps d'ouverture/ Turn off time Plage de frequence / Operating frequency range dv/dt etat bloque / Off state dv/dt dI/dt maximum non repetitif/ Maximum di/dt non repetitive I2t (<10ms) Possibilte de protection exterieure / External protection possibilty Symbol Ul Ulmin-max Up Usync Il nom Ua ( see Fig. 2 ) Il AC1 tp=10ms (Fig. 3) Itsm @ Il nom Vd @Ul, 50Hz Ilk Ilmin Uc nom DC ,f=50Hz ton max Uc nom DC ,f=50Hz toff max f dv/dt di/dt I2t Conditions Typ. 230 12-280 600 25 8 50 550 1,6 1 5 10 10 10-440 500 50 1500 Fuse Unit V rms V rms V V V A rms A V mA mA ms ms Hz V/s A/s A2s
Fig.2 Courbes thermiques /Thermal characteristics Relais double: 50A/ itsm=550A
160 0,3K/W
Fig.2 Courbes thermiques /Thermal characteristics
45
140 0,75K/W 120 2 ways 0,95K/W 100 Total dissipated power (W)
40 WF115000 (0,9C/W) 35 30 WF131100 (1,1C/W) 25 20 15 1LW27100(2,7C/W) 10 ON A PLATE(4C/W) 5 0 WITHOUT HEATSINK(12C/W) 0 10 20 30 40 50 60 70 80 90 100 1LW23100/WF262100 (2,2C/W)
80 1,6K/W 60 1 way 2,2K/W 40 6K/W
20
0 0 5 10 15 20 25 30 35 40 45 50 0 10 20 30 40 50 60 70 80 90 100
Courant par voie / Current by leg (A)
Temperature ambiante /Ambiant temperature (C)
RMS load current (A)
Ambient temperature (C)
Fig.3 Courbes de surcharge de courant / Overload current curves
Surge current Itsm (A peak) = f(t) 600 Itsm (Apeak)
for models with Itsm =550A
1 -Itsm non repetitif sans tension reappliquee est donne pour la determination des protections. No repetitive Itsm is given without voltage reapplied for the determination of the protection. 2 -Itsm repetitif est donne pour des surcharges de courant (Tj initiale=70C). La repetition de ces surcharges de courant diminue la duree de vie du Relais. Repetitive Itsm is given for inrush current with initial Tj = 70C. The repetition of the surge current decrease the lifetime SSR's .
400
200 0 0,01
0,1
t (s)
11
10
Proud to serve you
All technical caracteristics are subject to change without previous notice. Caracteristiques sujettes a modifications sans preavis.
r
celduc
e l a i
s
S/BIP/SCB945300/B/07/02/2003
Caracteristiques mecaniques /Mechanical specifications
28 24 19,6 44,5 28 O 4,7 M4 28 24 19,6
page 3 / 3 F/GB
=
celduc
40A
42,8
10,2
58
40A
47,6
L1
9906173L6
L2
I
T1 (12-280Vac)
10,2
230Vac
=
+
230Vac
(12-280Vac) SCB944300 with heatsink
MADE IN FRANCE
T2
Input 8-30Vdc
7,6
16 max
5,1
16 max
-Nde lot :9906173 Suivi du -Date code :L6 (juin 99) -Batch number : 9906173 following of -Manufacture date : L6 ( june 99)
Sorties / Outputs
Vis / screws : : M4 1,8 Nm
Entrees / Inputs
Section max de fil / Max. wire Screwdriver type : Couple de serrage /Screws torque : : 12 AWG 2,5 mm2 3,5 x0,5 mm 0,4 Nm
Couple de serrage / Screws torque
Tableau de sections de fil pour la gamme SC (Exemples) / Wiring tabs for the outputs SC range (exemples)
I max (A) Fil / wire (mm2) AWG/ MCM
L W W
L=22mm W=8,5mm <20 25 32 2,5 4 6 12 10 10 AMP : 0-0034160-0 L=27mm W=7mm AMP : 0-0034853-0 L=27mm W=7mm AMP : 0-0034853-0 L=23,7mm W=11,9mm AMP : 0-0032996-0
L=20mm W=6mm AMP : 0-0165012-1 L=31mm W=8mm AMP : 0-0132269-1 L=31mm W=8mm AMP : 0-0132269-1 x
Fils d'entree / Input wires
60,5 mm
50
10
8
Precautions : * Les relais a semiconducteurs ne procurent pas d'isolation galvanique entre le reseau et la charge.
Cautions : * Semiconductor relays don't provide any galvanic insulation between the load and the mains.
celduc
r e l a i s
www.celduc.com
Rue Ampere B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19


▲Up To Search▲   

 
Price & Availability of SCB945300

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X